[โ€“] catloaf@lemm.ee 8 points 1 month ago (1 children)

That's a pretty common failure scenario in SANs. If you buy a bunch of drives, they're almost guaranteed to come from the same batch, meaning they're likely to fail around the same time. The extra load of a rebuild can kill drives that are already close to failure.

Which is why SANs have hot spares that can be allocated instantly on failure. And you should use a RAID level with enough redundancy to meet your reliability needs. And RAID is not backup, you should have backups too.

[โ€“] kalleboo@lemmy.world 1 points 1 month ago

Also why you need to schedule periodical parity scrubs, then the "extra load of a rebuild" is exercised regularly so weak drives will be found long before a rebuild is needed.